So I bought a brand new NanoStation M5 and has the board and firmware XW 5.6xxx. I flashed it over to XW.v5.5.10-u2.28005.150723.1358 and all went well. Then flashed it to AREDN-3.16.1.0-ubnt-nano-m-xw-squashfs-factory. This also went ok, but now I can't get into the web ui to set it up. Yes I did change the computer over to receive IP automatically, using the right port on NanoStation. I tftp the factory XW.v5.5.10-u2.xxx back on it and it works, then flashed AREDN-3.16.1.0-ubnt-nano-m-xw-squashfs-factory back on it and same thing, can't get into setup. I think I am doing everything correct, I have flashed an NanoStation M2 2 weeks for this and all went well. Anyone have this problem or any ideas?
How did you downgrade to XW v5.5? This must be done via the AirOS GUI and not with the tftp method to work correctly.
Joe AE6XE
Yes, at the start I downgraded to XW v5.5xxx using AirOS GUI. Then put AREDN XW file on NS using AirOS GUI. After putting AREDN on it I can't get back into the setup. So the only way back in is tftp the factory restore file.
try holding the hardware reset button for 15 seconds (after power on and sufficient time to boot). This would ensure the AREDN firmware is initialized for 1st boot. Unless the device is faulty to begin with, the path you've taken is correct and it must be a cat5, laptop, or other issue.
can you verify, is your computer getting an IP address from the node? a 10.x.x.x address?
No, I don't think it is getting an IP, the computer says it is trying to verify the connection and can't. Maybe I can do a ipconfig and see what it says.
Also, when the node is in "pre-config" state, do you see it broadcasting on your PC's wifi as "MeshNode"??
Something is definitely wrong. Redone the whole process again. ipconfig comes up with an ip of 169.254.236.107. I have done a WiFi scan from computer and the node is not there. I have accessed one of my other nodes and done both WiFi and Mesh status and nothing.
[quote]ipconfig comes up with an ip of 169.254.236.107[/quote]
Do you get a default gateway of 169.254.236.xxx? if so, try going to 169.254.236.xxx:8080
I believe that I have done the 15 second reset with no results, I will try it again when I get back to it. I have done the long reset where the lights flash back and forth and then I do the tftp.
Thanks everyone for helping. I believe there is a problem with the nanostation, so it is going back to Amazon. Even with the Ubiquiti factory firmware it will kick me out when I change something and then apply, then I can't get back in again.
73's
Mike WE7AA
Are you using the Ubiquiti Device Discovery tool? Have you tried different browsers? Make sure your computer is set up to accept DHCP
Yes, I have tried the Discovery tool and it found the nanostation. But as soon as I change a setting anywhere and apply it will loose connection and you can't get back in without resetting. I have tried IE, Google Chrome internet browsers, no difference. I have the computer set a static ip so I can access Ubiquiti web interface and when flashed to AREDN I set it to DHCP. Here is the thing, one time I got it flashed to AREDN and was putting my callsign and password in and saved it, then when it rebooted I could not get back in again. I have flashed several Ubiquiti equipment and this is the first one that gave me problems. Also note, this happens whether I am in Ubiquiti firmware or AREDN firmware. I say something screwy with this nanostation!!
"I say something screwy with this nanostation!!" +1