You are here

Cudy TR‑3000 powers off after AREDN flash or reboot

1 post / 0 new
kf7yrs
Cudy TR‑3000 powers off after AREDN flash or reboot

I ran into a repeatable issue on the Cudy TR‑3000 after flashing AREDN:

  • The flash process completed normally

  • As soon as the node rebooted, it powered off completely (no LEDs)

  • Any manual reboot also resulted in a full shutdown instead of coming back up

    Solution: check the side boot‑selector switch

The TR‑3000 has a small 2‑position slide switch on the side of the unit, next to the reset button. Cudy doesn’t document it well, but it functions like a boot‑source selector (similar to GL.iNet’s NAND/NOR switch).

If this switch is in the recovery position during or after flashing AREDN, the bootloader tries to load the wrong partition. The kernel can’t mount the expected rootfs, and the hardware watchdog shuts the device down instead of rebooting.

Flipping the switch to the other position immediately fixed the issue. After that, the node boots normally in ~30 seconds and reboots cleanly every time.

Symptoms that match this issue

  • Device powers off immediately after flashing AREDN

  • Reboots result in a full shutdown

  • No LEDs after reboot

  • Device only comes up when power‑cycled manually

If your AREDN-flashed TR‑3000 shuts down instead of rebooting, check the side switch first. Try both positions — one will allow AREDN to boot normally.